Fall arrest safety nets are essential for protecting workers at height, but regular testing and inspection are necessary to ensure they remain safe and fit for use.
In the UK, safety nets in service should undergo material testing at intervals of no more than 12 months, in accordance with FASET industry guidance. Nets installed on site should also be inspected by a competent person at intervals not exceeding seven days, as well as following adverse weather or incidents that could affect their integrity.
These are two different requirements: annual testing assesses the netting material's performance, while regular inspections check the condition and security of the installed system.
This guide explains the relevant UK regulations, BS EN 1263 standards and FASET recommendations, helping contractors and site managers understand their responsibilities.
Safety Net Testing and Inspection: At a Glance
|
Requirement |
Frequency |
Purpose |
|---|---|---|
|
Material / UV degradation testing |
At intervals no greater than 12 months |
Verify the net still meets the manufacturer's withdrawal-from-service criteria |
|
Installation and handover inspection |
Before the system is put into use |
Confirm the net is correctly installed |
|
Routine on-site inspection |
At intervals not exceeding 7 days |
Check the integrity and security of the installed system |
|
Pre-use visual check |
Before work above the net |
Identify visible damage or other concerns |
|
Additional inspection |
After adverse weather, impact or other potentially damaging events |
Establish whether the system remains safe |
**The intervals reflect FASET guidance and HSE's weekly inspection advice. The Work at Height Regulations 2005 impose the underlying inspection duties; they do not prescribe every interval shown in the table.
Why do safety nets need testing?
Most fall arrest nets are made from polypropylene or nylon. Like most textiles, both are weakened by ultraviolet (UV) light from the sun. A net can look perfectly sound and still have lost strength, and a net’s whole job is to absorb the energy of a person falling into it.
For that reason, FASET’s bulletin on UV degradation requires every net in service to have been tested within the previous 12 months, to prove it still meets or exceeds the manufacturer’s withdrawal-from-service level. That is the minimum strength set for that particular net.
The product standard, BS EN 1263-1:2014, sets the safety requirements and test methods for nets made from polypropylene and polyamide fibres. BS EN 1263-1 specifies safety requirements and test methods for safety nets, while BS EN 1263-2 addresses safety requirements for their positioning and installation. Both are relevant to the safe use of fall arrest netting.
What does the law say about inspecting and testing safety nets?
There is no single regulation that says “test your net every 12 months”. The legal duty to inspect comes from regulation 12 of the Work at Height Regulations 2005, and FASET explains in its Bulletin SN30 that safety nets fall within it through regulation 8 and Schedule 4. In plain terms, employers must make sure that:
- Reg. 12(2): where safety depends on how equipment is installed, it is inspected in position before it is used.
- Reg. 12(3): equipment exposed to conditions that cause deterioration is inspected at suitable intervals, and each time exceptional circumstances occur that could jeopardise its safety.
- Reg. 12(6): the result of each inspection is recorded and kept until the next one is recorded.
- Reg. 12(10): “inspection” means a visual or more rigorous inspection by a competent person, and it includes any testing appropriate for safety purposes.
The 12-month mesh test is how the industry meets the testing part of that duty for UV degradation.
Where does the 7-day figure come from?
Regulation 12 does not set a number of days for safety nets. It requires inspection “at suitable intervals”. FASET’s guidance is that, for safety netting, those intervals should not exceed seven days.
The only 7-day wording in regulation 12 is in paragraph (4), and it applies to working platforms used for construction work from which a person could fall 2 metres or more. It does not apply to nets. So the accurate way to put it is: the law requires inspection at suitable intervals, and FASET guidance sets the benchmark at seven days.
The 12-month UV test, step by step
- Test meshes are supplied with the net. A new net is normally supplied with three test meshes, loosely attached. Each carries its own serial number, traceable to that net.
- One mesh is removed and tested at least every 12 months. FASET’s FAQs state that no more than 12 months should pass between tests.
- The test itself. FASET Bulletin SN02 sets out the common standard: a tensile test across a single cell, at a speed of 300 mm per minute, on a machine calibrated to BS EN ISO 7500-1:2004. Manually operated machines must not be used, and testers must be competent and trained on the device. The FASET FAQs refer to ISO 1806 for the method.
- The result is compared with the manufacturer’s withdrawal-from-service level, which is shown on the manufacturer’s label or certificate of conformity.
- Pass or fail: The test result is compared against the manufacturer's specified withdrawal-from-service level. If the sample passes, the net may remain eligible for use for a further period not exceeding 12 months, provided it also satisfies all other applicable safety and inspection requirements.
Where a sample falls below the required level, the net must be taken out of service. FASET Bulletin SN02 permits one retest in certain circumstances where the result is less than 5% below the withdrawal threshold. If the net does not satisfy the applicable acceptance criteria, it must be permanently withdrawn from service.
- The result is recorded. FASET Bulletin SN01 sets the minimum content of a test record: the testing company, the competent person who carried out the test, the net owner, the date, the test speed, the manufacturer’s withdrawal level, and the result (a fail, or confirmation that the net may be used for a further 12 months). The netting contractor should keep the written evidence at least until the following year’s result is available, and FASET recommends keeping every result for the life of the net.
- Test identification and records: Following a successful test, a suitable test tag should be attached to the net, identifying the testing company, test date, next test date and pass result, in accordance with FASET guidance.
Although the FASET FAQs distinguish test tags from the formal requirements of BS EN 1263, FASET's technical guidance recommends their use to make test status easier to verify on site. Written test records must also be maintained, and a test tag should never be treated as a substitute for the relevant documentation.
What if all three test meshes have been used?
The net does not have to be retired. FASET Bulletin SN02 allows further test meshes to be created by cutting a patch from within the same net. The patch is then repaired in line with FASET guidance.
How can you check that a net is in test?
FASET’s FAQs give principal contractors four practical checks:
- Ask for the written history. The netting contractor should be able to supply the test record for each net.
- Read the identification label. Every net should carry the date of manufacture, the net system and class, the net size, a reference to BS EN 1263-1:2014 and a unique serial number.
- Count the remaining test meshes. With three fitted at manufacture, you would expect roughly two to remain after the first year and one after the second. This does not prove a net passed its test, but it is a simple sign that the contractor has a system for removing samples.
- Check the test tag where fitted. This should show the relevant testing details and next test date. Confirm the information against the net's identification and test records.
How often should safety nets be inspected?
Testing tells you about the material. Inspection tells you about the whole installation, and the two work together. FASET’s guidance sets out this sequence:
- During rigging and at handover, by a competent person.
- Before each use, by the people working above the net (a visual check).
- Every 7 days after handover, by a competent person, for as long as the net continues to be worked over.
- After adverse weather, impacts, tampering, or removal or wear of components.
- After each contract, ideally back at the rigger’s premises for a formal inspection (FASET describes this as good practice).
Wind and snow matter more if a debris mesh has been fitted over the net, because neither passes through it easily. If a net has been loaded in this way, a competent person should inspect it before the next use. Debris overlay also makes the regular inspections harder, so allow for that.
What a competent person looks for
- The identification label is legible and the serial number matches the records.
- The test mesh count, test tag and next test date are in order.
- The mesh is free of cuts, holes, fraying, abrasion, broken knots and stitching failures, and shows no discolouration.
- The border rope is full and continuous with a spliced joint (for a Type S net, FASET gives a minimum breaking strength of 30 kN).
- Attachments are secure. With rope ties, the maximum centres are 2.5 m, and proprietary devices may need closer spacing, so always follow the manufacturer.
- Gaps between the net and the structure are no more than 100 mm wherever practical, and up to 225 mm only in exceptional circumstances such as lacing around columns.
- Debris has been cleared, and nothing has been tampered with or removed.
What happens after a fall into a net?
A net deforms to absorb the energy of a fall, and how much it stretches depends on the height, the weight of the person or materials, and where they land. FASET Bulletin SN20 explains that it is not possible to predict how a loaded net would perform in a second fall. BS EN 1263-1 says a net should be checked by a competent person after loading, which is generally the manufacturer rather than the rigging company. FASET therefore recommends that safety nets should only be loaded once.
In practice:
- Take the net out of use straight away and do not reuse it until a competent person has advised that it is safe.
- Treat falls of significant materials, goods or plant the same way as a person falling.
- Report the fall to the rigging company, site management and the company with workers above or next to the net. FASET also collects reports through its website and shares statistics with the HSE.
Keep Your Safety Nets Tested and Ready for Use
Regular safety net testing is an important part of maintaining a reliable fall arrest system. By keeping testing records up to date, carrying out routine inspections and addressing any signs of deterioration, contractors can help ensure their safety nets remain suitable for use.
At Boris Nets, we provide specialist safety net testing services, helping businesses assess netting condition and verify that tested samples meet the manufacturer's specified performance requirements.
Whether you need annual UV degradation testing or guidance on your netting requirements, our experienced team is here to help.